Diaphragm pump N952KTE-W N952KT.29E-W
Translation of Original Operating and Installation Instruction, KNF 339866-336533
02/23
Connecting the pump
CAUTION
1. Remove the protective plugs from the hose connection
threads.
2. Connect the suction line and the pressure line (for mount-
ing dimensions, see Chapter 3 Technical data [} 14]).
3. Lay the suction line and pressure line with a descent so
that no condensate can run into the pump.
Risk of injury from mixing up suction
side and pressure side
Mixing up the suction side and pres-
sure side can result in breakage of
connected components on the suction
side and pressure side.
à
Observe the marking of inlet and
outlet on the pump head.