Hilti UH 700 Manual De Instrucciones Original página 15

Ocultar thumbs Ver también para UH 700:
Idiomas disponibles

Idiomas disponibles

Diameter, chuck
Tightening torque for change of chuck
5
Use of extension cords
Using extension cords
WARNING
A damaged supply cord presents a hazard! Do not touch the supply cord or extension cord if damaged
while working. Disconnect the supply cord plug from the power outlet.
▶ Check the appliance's supply cord at regular intervals and have it replaced by a qualified specialist if
found to be damaged.
Use only extension cords of a type approved for the application and with conductors of adequate gauge
(cross section). The power tool may otherwise suffer a drop in performance and the extension cord may
overheat.
Check the extension cord for damage at regular intervals.
Replace damaged extension cords.
When working outdoors, use only extension cords that are approved and correspondingly marked for
this application.
Information on recommended minimum conductor cross-sections and cable lengths is accessible via
a link, in the form of a QR code, at the end of this document.
6
Preparations at the workplace
CAUTION
Risk of injury! Inadvertent starting of the product.
▶ Unplug the supply cord before making adjustments to the power tool or before changing accessories.
Observe the safety instructions and warnings in this documentation and on the product.
6.1
Fitting and adjusting the side handle
1. Release the side handle clamping band by turning the handle grip.
It is essential to ensure that the sleeve is fitted in the grip of the side handle.
2. Slide the side handle holder (clamping band) over the chuck and into the recess provided.
3. Set the side handle to the desired position in accordance with the detents.
Make sure that the ribs of the clamping band are snug in the grooves on the gearing section.
Otherwise the side handle will no longer be able to transfer the torques generated by the tool.
If the side handle slips because the drill bit stalls, check the positive lock/ribs on the gearing section.
4. Tighten the side handle holder (clamping band) by turning the handle grip.
6.2
Fitting and adjusting the depth gauge
1. Release the locking screw.
2. Slip the depth gauge into the opening provided for the purpose.
3. Adjust the depth gauge to the desired drilling depth.
4. Firmly tighten the locking screw.
*273762*
2
3
273762
UH 700
1.5 mm ... 13 mm
(0.06 in ... 0.5 in)
120 Nm
(89 ftlb
)
f
English
7