Connecting the inverter
8.3
Mounting the inverter
➤ Hold the inverter against the installation location and mark the fastening
points (fig. 3 A, page 3).
➤ Attach the inverter using your chosen fastening method (fig. 3 B,
page 3).
9
Connecting the inverter
9.1
General instructions
!
WARNING!
The inverter may only be connected by a qualified workshop.
The following information is intended for technicians who are
familiar with the guidelines and safety precautions to be
applied.
Never use the inverter on vehicles where the positive terminal
of the battery is connected to the chassis.
If you do not fit a fuse to the positive cable, the cables can
overload, which might result in a fire.
Reversed polarity can damage the inverter.
The inverter should not be used to connect to a ring main, it
must only be used to power individual appliances that are
plugged into the inverter outlet either directly or using a pur-
pose-made, moulded extension lead
When installed in vehicles or boats, the inverter must be connected to the
chassis or earth.
When setting up a socket distribution circuit (mains setup), comply with
the applicable regulations.
Only use copper cables.
Keep the cables as short as possible (< 1.8 m).
Keep to the specified cable cross section and fit a cable fuse (fig. 6 3,
page 5) as close to the battery as possible on the positive cable (see the
table).
Device
MSI924M
38
Required cable
cross section
25 mm²
MSI924M
Cable fuse
(fig. 6 3, page 5)
75 A
EN