7.3.7. RECALL OF MEMORISED BLAST CHILL/SHOCK FREEZE PROGRAMME
To select a blast chill/shock freeze programme press button
memorised programmes are displayed in sequence (Fig.14). Press button
(Fig.14)
selected blast chill/shock freeze programme. If DISPLAY 2 (Fig.13) indicates symbols
there are no memorised programmes.
7.4. DEFROSTING
Manual defrosting occurs if the cabinet temperature is below parameter P57 (see tecincal manual).
To start a defrosting cycle press the
open. DISPLAY 1 indicates the code
(Fig.15)
7.5. STERILISATION (optional)
Sterilisation can commence only if the temperature is above parameter P26 (see tecincal manual).
The cycle is activated with the machine in Stand-by by pressing the
ispressed again, the cycle is terminated. The
sterilisation phase is in progress. DISPLAY 1 shows the time to the end of the process.
If the door is opened or a blackout occurs, sterilisation is interrupted (Fig.16).
(Fig.16)
7.6. PRINTER (optional)
If the printer is present, the following is recorded for every blast chill cycle: date, time, type of cycle,
time elapsed from start of cycle and cabinet and core temperature sampled every 10 minutes.
For recording lower or higher than 10 minutes, change the parameter P44 (see tecincal manual).
Using parameter P86 (see technical manual) the language of the printer can be changed.
****HELLO****
03/03/2007
+3°C HARD
Time
Ti
00:00 25
00:10
8
10:15
SP1 SP2 SP3 SP4
54
52
51
49
45
44
42
40
button for extended time with the machine in
and DISPLAY 2 the cabinet temperature (Fig.15).
symbol lit up on the display indicates that the
= time elapsed
Time
= CABINET temperature
Ti
= sensor 1 multi-point pin probe point
SP1
= sensor 2 multi-point pin probe point
SP2
= sensor 3 multi-point pin probe point
SP3
= sensor 4 multi-point pin probe point
SP4
, by pressing the
, to commence the
, button. When the button
27 - GB
or
the
door