Energy saving mode
Energy saving mode activates the heating when the temperature drops below "T eco on" and
heats up to "T eco" + hysteresis when solar load or solid fuel boiler is active.
Thermostat times
Thermostat activity times
The desired times when the thermostat function is approved are set here. Three times can be
specified for each day of the week, and individual days can be copied to other days. The ther-
mostat function is switched off outside the set times.
Thermostat 2
Through the thermostat function it is possible to add energy to the system, simultaneously con-
trolling the time and temperature (see "Thermostat" on page 163)
Temperature values set too high can cause overheating or damage to the system.
Overheating protection must be the user's responsibility!
Other values, e.g. Teco, apply in Eco mode.
Tset
Target temperature in the probe set for the dissipation function (simple cooling).
Hysteresis
When the Tset + hysteresis value is reached on the cooling probe, the relay is deactivated.
Cooling probe
Cooling function reference probe.
Times
Cooling operation times
The desired periods in which the cooling function is approved are set here. Three times can be
specified for each day of the week, and individual days can be copied to other days. Outside
these times, the cooling function is deactivated.