Off; Settings; Tmin S1: Start/Activation Temperature In Probe 1; Storage Priority X: Two-Storage System - Ferroli ECOTRONIC HiTech Manual Del Usuario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

The "Manual" operating mode can only be used by personnel in charge for short
function tests, e.g. during startup! Function in manual mode: the relays and con-
nected components are switched on and off by pressing a button, regardless of
the current temperatures and the set parameters. At the same time, the current
measured values of the temperature sensors are also shown on the display for
function control purposes

3.3 Off

If the "off" operating mode is enabled, all control functions are deactivated. The
measured temperatures are displayed.

4. SETTINGS

Exit settings
4.1.T min S1
4.4.
T Solar S2 10°C/3°C
D
Under no circumstances does the controller replace the on-site safety devices!
4.1 Tmin S1: Start/activation temperature in probe 1
If this value on probe 1 (collector probe) is exceeded and the other conditions have been met,
the controller activates the associated pump or valve. If the temperature of probe 1 drops 5 °C
below this value, the pump or valve will be deactivated again.
4.2 Storage priority X: two-storage system
Storage priority in a multi-storage system. The order in which the storage tanks are heated is
set here. If the same priority is set for 2 storage tanks, loading is switched only after the active
storage tank is filled.
Example: If more storage tanks or storage areas are integrated into the system, it is possible
to specify a priority for each storage tank or storage area probe. The "X" in the
priority of the menu items S(X) indicates the probe of the relevant storage tank or
storage area.
The priority for the first storage tank is then set under priority S2 and for the 2nd
storage tank under priority S3.
154
EN
20°C
info
code 3542A420 - Rev. 00 - 12/2021
ECOTRONIC HiTech
Tabla de contenido
loading

Tabla de contenido