WARNING: before connecting to the generator, confirm if all equipment is in
good working conditions.
If the equipment runs abnormally, slowly or spontaneously shuts down, stop the
generator immediately and disconnect the equipment.
To improve engine performance and to give more life to the generator, a running-
in (without forcing the engine) period of 20 hours is recommended, with a power
consumption up to 60% of the maximum power produced by the generator.

7.2 Control pilots

Upper pilot: Low oil level
With a low oil level, this indicator turns on. Consequently, for security reasons, the
engine turns off. The engine only start again if the oil level is restored.
If you try to start the engine with a low oil level, it will not start and the indicator will
flash during all starting attempts.
The lack of oil alarm is designed to avoid damage to the engine caused by
insufficient oil in the motor.
NOTE: Protection due to lack of oil must be considered an extra security.
Checking the oil level before each use is the full responsibility of the user,
as indicated in this manual. The probability of the alarm system fail is very low,
but if the checking also fails, the damage on the engine will be very high. Thus,
unique and exclusively, the user is responsible for any damage due to lack
of maintenance. This kind of damage is not covered by warranty.