Selecta STERIL-FOOD 80L Manual De Instrucciones página 44

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

INSTRUCTION MANUAL
PRE
80ºC
P03
PUR
98ºC
05m 00s
/
1
121.0ºC 00h 03m +1.60bar
pRobe
heaRt
2
80.0ºC 00h 05m +1.60bar
F
/
o
SteRile
F
/
o
t
ime
Selection: water or heart probe
Selection: from the lethality table:
Fo Sterilization (default)
Fo Pasteurization A
Fo Pasteurization B
Selection of the "end of step" condition:
Fo: The end of step occurs when the Fo which
corresponds to the programmed temperature and
time is reached (recommended).
Time: The end of step occurs when the program-
med temperature and time have elapsed.
Generally the Fo "end of step" is faster.
(if heart probe is used)
PROGRAMACIÓN
AJUSTES
PROGRAMMING
SETTINGS
TRABAJO
TASK
Program number
Program step
P03
PRE
80ºC
PUR
98ºC
05m 00s
1
121.0ºC 00h 03m +1.60bar
2
80.0ºC 00h 05m +1.60bar
Sel
CALENTANDO
Select the program
J
.P. SELECTA s.a.u.
CODE 80342 REV H
7.9 Create or modify a program
back
- Click on «PROGRAMMING».
- Select a program to modify it.
add
Click on the arrows
moRe
The programs are numbered P01, P02, P03, ....
Save
(Each program can have up to 6 steps)
To modify / create a program, click on «EDIT».
- Press directly, with your finger or a pointer, on the temperature, time,
pressure to modify its value.
- Click on the "step" number to delete it or add a new one.
- Select the temperature control probe:
• Heart probe: (Recommended in Twist-off)
(Located inside the product to ensure that the heat treatment has reached
the most difficult point.)
• Water probe: (Only in specific cases, sealed bag)
(Located in the lower part of the boiler, submerged in the water. Indicates
the water temperature.)
Press SAVE to save the program.
Press BACK to exit the programming screen.
See section 5.2 for more details.
7.10 Starting a program
Click on «PROGRAMMING» to select the program.
Click on the arrows
back
The programs are numbered P01, P02, P03, ....
(Each program can have up to 6 steps)
edit
TIEMPO TOTAL: 00
46
23
h
M
S
Press to edit the program
Autovía A-2 Km 585.1 Abrera 08630 (Barcelona) España
e-mail: [email protected] - website: http://www.jpselecta.es
JAN/2020
(It can be modified without notice)
to select the program to be modified.
to select the program.
Tel 34 937 700 877 Fax 34 937 702 362