Control Function Test; Wet Clean Processing - Alliance Laundry Systems UW35PV Instalación/Mantenimiento

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Control Function Test

The washer-extractor should be cleaned after
the installation is complete. A function test
should then be executed on the unloaded
machine:
1. Check the power supply for such
characteristics as correct voltage, phase,
and cycles to be certain they are correct for
the washer-extractor.
2. Open manual shut-off valves to
the washer-extractor.
3. Press the Emergency Stop button.
4. Apply power to the washer-extractor.
5. Release the Emergency Stop button by
turning to the left then pulling button
sharply.
6. Check the door interlock before
starting operation:
a. Attempt to start the washer with the
door open. The washer should not start
with the door open.
b. Close the door without locking it and
attempt to start the washer. The washer
should not start with the door unlocked.
c. Close and lock the door and start a
cycle. Attempt to open the door while
the cycle is in progress. The door
should not open.
If the door lock and interlock are not
functioning properly, call a service
technician.
7. For standard processing, select Cycle 01
by pressing key 0 and key 1 on the keypad.
Then press the Start key.
Run a complete cycle, checking operation
of all functions.
F232084
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation
8. Cylinder rotation must be clockwise in the
extract step. If rotation is not clockwise in
the extract step, disconnect power. A
qualified electrician must reverse any two
leads between the AC drive and the motor.
See Figure 18.
If the washer-extractor is served by the
Premium Wet Clean Module, continue the
control function test with the following
procedure:

Wet Clean Processing

For wet clean processing, program the
standard test cycle to verify proper operation
of the wet clean system. (Refer to the
UWPV Operation/Programming manual, Part
No. F232089.)
Run the test cycle and verify that the wet clean
system is operating properly:
• Check plumbing connections for
leaks.
• Verify that the Premium Wet Clean
Module pump is operating properly,
and that the rotation direction is
counterclockwise. If rotation
direction is incorrect, a qualified
electrician must reverse any two
leads.
• Verify that the drain valve on the
Premium Wet Clean Module opens
and closes properly.
• Verify that canister lid does not leak.
41

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Uw80pvUw125pvUw60pvUw100pv

Tabla de contenido