The terminal strip that furnishes the supply
output signal for the chemical injection supply
pumps, is located inside the control module at
the rear. Access is through the rear panel of the
module.
Terminals
through
SUPPLY 1
common provide 200-240VAC fused at 500mA.
These terminals may be used to provide signals
to the chemical injection system but must not be
used to provide power to the pump. Do not
attempt to increase fuse rating as this may cause
damage to the washer-extractor's circuitry.
An external chemical injection system requiring
200-240VAC can be powered through LINE 1 and
LINE 2 on the external supply terminal strip on
UWPVQ and PVT models. Any chemical
injection system used with UWPVN and UWPVP
models must be powered by a separate external
power source.
F232084
and
SUPPLY 9
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation
Any injection system pump which requires
110VAC must be powered by a separate
external power source.
CAUTION
Attempting to obtain 110VAC by using L1 or
L2 with the common may damage laundry
machine circuitry and/or the chemical
injection system. Using a 240VAC power
wire in the washer-extractor and an earth
ground to obtain 110VAC could cause
microprocessor problems.
Consult the chemical injection supply system
instructions for operational details.
SW028
35