Installation
UWPV Pocket Hardmount General Specifications (Continued)
Average power used per cycle, kW/hr
Average HVAC load, BTU/hr
(kcal/hr)
Number of motors in drive train
Drive motor power, hp (kW)
1/2 Wash/reverse, rpm (g)
Wash/reverse, rpm (g)
Distribution, rpm (g)
Medium extract, rpm (g)
High extract l, rpm (g)
*Design U6 models
High extract 2, rpm (g)
High extract 3, rpm (g)
*Design U6 models
Vibration safety switch installed
Safety switch gap setting, in (mm)**
* Reference Figure 1, page 12, and serial number decal on machine to determine design series.
** Gap setting should be made with "GO–NO-GO" type feeler gauge.
14
35
Power Consumption
0.18
800 (202)
Drive Train Information
1
3.0 (2.2)
Cylinder Speeds / Centrifugal Force Data
26 (.25)
42 (.66)
83 (2.57)
325 (39)
474 (84)
533 (106)
610 (139)
795 (235)
897 (308)
Balance Detection
STD
.006 (.15) GO
.008 (.20) NO-GO
.010 (.25) NO-GO
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
60
80
0.28
0.48
950 (240)
1050 (265)
1
1
5.0 (3.7)
7.5 (5.6)
26 (.31)
26 (.35)
40 (.73)
40 (.82)
71 (2.29)
73 (2.57)
305 (42)
325 (54)
435 (86)
408 (85)
483 (106)
456 (106)
555 (140)
523 (140)
720 (235)
671 (230)
813 (300)
767 (300)
STD
STD
.008 (.20) GO
.008 (.20) GO
.010 (.25) NO-GO
100
125
0.48
0.60
1150 (290)
1200 (302)
1
1
7.5 (5.6)
10 (7.5)
26 (.35)
26 (.40)
40 (.82)
37 (.82)
70 (2.50)
62 (2.29)
325 (54)
260 (40)
408 (85)
380 (86)
456 (106)
N/A
523 (140)
485 (140)
601 (184)
580 (200)
767 (300)
N/A
STD
STD
.008 (.20) GO
.008 (.20) GO
.010 (.25) NO-GO
.010 (.25) NO-GO
F232084