Operation

Test Cycle

Cycle number 01 is a test cycle used to analyze
washer-extractor functions. Refer to the Programming
section of this manual.
Step 01 in cycle number 01 is a cold fill to low level.
This step is designed to give not quite enough time to
complete a fill, causing the display to read "FILL".
Press the Start key to continue the fill, and the test
cycle will proceed.
Step 02 in the test cycle is a drain step. Again, the time
allotted is shorter than it would be in a normal cycle.
The display will read "EMTY". To proceed, press the
Start key.
The steps in the test cycle are relatively short, with the
exception of steps 03, 21, 25, 27, 28, and 29. These
can be shortened by pressing the Advance key to go on
to the next step.
The operator may skip to any next step in the cycle
with the exception of a drain step; drain steps must be
allowed to complete. To skip forward in the test cycle,
press the Advance key.
28
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Wet Clean Testing

Wet clean processing outputs are tested through the
energizing of the Auxiliary 1 output in step 18 and
Auxiliary 2 output in step 19. Steps 30 through 33 are
designed to test water reuse processing, if this option
is installed. If it is not, the outputs associated with
each step will be energized, and the cycle will
conclude normally.
NOTE: Prompts for "1DRAIN" and "WET CL"
must be selected when prompting the WE-6
microcomputer in order for steps 18 and 19 to
work properly for wet clean processing.
NOTE: The Advance feature may be disabled.
Refer to Prompting the WE-6 in the Programming
section of the manual.
F232101