Maintenance Schedule; Maintenance Replacement Parts; Air Filter Maintenance - Westinghouse WGen9500DFc Manual Del Usuario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

MAINTENANCE
MAINTENANCE
Accidental start-up. Disconnect the spark plug boot from
the spark plug and disconnect the battery quick-connect
plugs when performing maintenance on the generator.

MAINTENANCE SCHEDULE

Regular maintenance will improve performance and
extend the service life of the generator. Follow the hourly
or calendar intervals, whichever occurs first. More frequent
service is required when operating in adverse conditions
as noted below.
Before Each Use
Check engine oil
After First 25 Hours or First Month
Change engine oil
After 50 Hours or Every 6 Months
Change engine oil
Clean air filter
After 100 Hours or Every 6 Months
Inspect/clean spark arrestor
Inspect/clean spark plug
Replace fuel filter
Fuel valve maintenance
Inspect/adjust valve clearance
After 300 Hours or Every Year
Replace spark plug
Replace air filter
Change oil every month when operating under heavy
1
load or in high temperatures.
Clean more often under dirty or dusty conditions.
2
Replace air filter if it cannot be adequately cleaned.
Recommend service to be performed by authorized
3
Westinghouse service dealer.

MAINTENANCE REPLACEMENT PARTS

Description
Air filter
Oil drain plug crush washer
Spark arrestor
Battery, 14 AH
Fuel filter
Spark plug
24 | Westinghouse Outdoor Power Equipment, LLC
WARNING
1
2
3
Part Number
5692
94004
6866
511012
516401
91708 (F7TC)
MAINTENANCE REMINDERS
Maintenance reminder codes will be shown on the Data
Display based on unit Lifetime Hours. The maintenance
codes will be displayed until the unit is turned off. Refer to
the Maintenance section for specific procedures.
Maintenance Code Required Maintenance
P25
Change engine oil
P50
P100

AIR FILTER MAINTENANCE

Fire hazard. NEVER use gasoline or other flammable
solvents to clean the air filter. Use only household
detergent soap to clean the air filter.
The air filter must be cleaned after every 50 hours of use or
six months (frequency should be increased if the generator
is operated in a dusty environment).
1. Place the generator on a level surface and allow the
engine to cool for several minutes.
2. Release the top and bottom clips then remove the air
filter cover.
3. Remove the air filters. Use compressed air to clean the
coarse air filter.
Note: The foam air filter element is oil soaked. Use an
appropriate cleaning container.
Avoid skin contact with engine oil. Wear protective
clothing and equipment. Wash all exposed skin with
soap and water.
• Change engine oil
• Clean air filter
• Change engine oil
• Clean air filter
• Fuel valve maintenance
• Replace fuel filter
• Inspect/adjust valve clearance
WARNING
NOTICE
Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Wgen7500dfc

Tabla de contenido