Commissioning - Bosch Rexroth KE312 Manual Del Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 32
14/48 Bosch Rexroth AG | Electric Drives and Controls

5 Commissioning

5
Commissioning
Before commissioning, the proper seat of all
jumpers must be ensured. For commission-
ing, proceed as follows:
1 Remove the isolating strips between the
holder and the battery, and check to see if
the battery is properly inserted in the bat-
tery holder. If not, insert a battery accord-
ing to the instructions in section 4.1.
2 Insert the KE312 into the system box.
3 If applicable, insert the SMxxx interface
modules in the KE312.
4 Close off slots that are not occupied with
interface modules (X14, X16) using dum-
my panels (see section 5.3).
5 Turn on the voltage supply for the system
box.
6 Connect the operating computer and set
the time with the BS300 system.
7 Configure the interfaces and program the
tightening system.
5.1
Display elements
Two LEDs are installed on the front panel of
the KE312 communication unit which indi-
cate the operating states:
LED
LED
Figure 3:
* Possible causes: Sequence test,
initialization is still running
The KE312 can only be reset using the
LT/LTU reset button in the system box.
Red, flashing
System error
Green
Ready for operation
Green, flashing Not ready for operation
Red/green,
Data traffic active
flashing
KE312 | 3 609 929 987/1.0
5.2
Interface X 11: RS232
This interface is intended to connect a pro-
gramming device or an SD301.
1
5
6
9
Figure 4: Sub-D plug, 9-pin
Pin Signal Description/
Function
1
-
2
RxD
RS232 Receive
3
TxD
RS232 Send
4
24 V
24 V Power
supply for SD301
5
GND
Reference
Potential Logic
6
-
7
RTS
RS232 Request
Send
8
CTS
RS232 Enable
Send
9
-
Table 3:
5.3
Slots X14, X16: Slots for inter-
face modules
*
Two module card slots are available for ex-
pansion of the communication unit. These
can be equipped as follows:
Module
Field bus: Interbus-S SMibs
Field bus: Profibus DP SMpdp 0 608 830 165
Field bus: DeviceNet SMdev
Parallel: 24 V I/O SM24V
Serial: RS 232, RS 422,
20 mA SMser
Network: Ethernet SMeth
Table 4:
Voltage/
Current/
Standard
–12 V...+12 V,
RS232
–12 V...+12 V,
RS232
24 V=, 300 mA
–12 V...+12 V,
RS232
–12 V...+12 V,
RS232
Order number
0 608 830 164
0 608 830 248
0 608 830 166
0 608 830 167
0 608 830 168
Tabla de contenido
loading

Tabla de contenido