Thermometer Overview; Initial Set Up; Section Ii Safety And Warnings; Indications For Use - Covidien Genius 3 Manual De Instrucciones

Ocultar thumbs Ver también para Genius 3:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 85
Section I — Thermometer Overview
The Genius™ 3 Tympanic Thermometer is an ADJUSTED MODE ear thermometer that provides fast and accurate measurements of
patient temperatures. The Genius 3 Tympanic Thermometer is an ear canal thermometer with measurement site adjusted modes,
which include oral and rectal temperatures. The site modes are explained further in Section IV, Instructions for Use.
This operator's manual was prepared for the operator, lay operator and lay responsible organization to use the Genius™ 3
Tympanic Thermometer and Base. This manual contains instructions for use, precautions, and available maintenance and service
information. For accurate results, the operator must read this manual thoroughly before attempting to use the thermometer.

Initial Set Up

• Unpack the thermometer and check it for damage.
• If using the wall or cart mount (sold separately) for the base unit, refer to the installation sheet.
• When first used, the thermometer will show the default settings: ear mode (EAR) and the Celsius scale (°C).
• If the thermometer has been stored outside of the listed ambient temperature range (see section X), allow thermometer to
acclimate to the room temperature for a minimum of 30 minutes prior to use.
Features
• Temperature measurement meets ISO standards – See Section X
• Peak Select System – See Section IV Instructions for Use
• Temperature measurement range of 33.0°C to 42.0°C (91.4°F to 107.6°F)
• After a temperature has been acquired, the °C/°F button changes between °C and °F
• Audible and visual indication of completed temperature measurement
• Disposable single use probe covers designed to aid in the prevention of cross contamination
• Low and dead battery indicators
• "Sleep" mode stores the last temperature and saves battery life
• 15, 30, 45, and 60 second pulse timer functions
• The thermometer housing can be wiped clean with common cleaning agents – See Section VI, Cleaning for instructions
• Base unit protects the thermometer tip and stores probe covers for easy access
• Easy to read LCD display with icons
• Unit is designed for right and left hand use
• Provides temperature measurement in 1 - 2 seconds
Section II — Safety and Warnings
Note to healthcare personnel who provide training to lay operators or lay responsible organizations:
Be sure to include all of the Dangers, Warnings and Cautions below when providing training to Lay Operators, especially for
home care use. Lay Operators should be instructed to contact Customer Service if there is a change in the performance of the
thermometer. Additionally, Lay Operators should be instructed on proper cleaning procedures to avoid hazards such as cracks or
water ingress. Lay Operators should also be trained on proper use (e.g. out of range ambient temperatures) of the thermometer.
For guidance on training, please contact Customer Service.

Indications for Use:

The Genius 3 Tympanic Thermometer is intended for use in patients in acute and alternative care settings to provide temperature
measurements from the tympanic membrane and equivalent measurements of oral and rectal temperature based on the
tympanic reading.
Danger:
• Thermometer cable could lead to strangulation.
• Swallowing of Probe Cover could lead to serious medical injury.
• Used probe covers must be treated as infectious biological waste. They must be disposed of in accordance with current
medical practices and local regulations.
Tympanic Thermometer and Base
1
en
Table of Contents
Tabla de contenido
loading

Tabla de contenido