6. Maintenance
Remove the cover (H) from the rotors;
10.
Remove the 3 fixing bolts for each knife
11.
to disassemble them from the two rotors.
Replace all knives of the two rotors with
12.
new ones;
Make sure the knives' bolts are in good
13.
condition. If necessary, replace them as
well.
After replacing the knives, mount all
14.
removed items to perform the procedure.
IMPORTANT!
After replacing the rotor knives, adjust
the knives with the counter knife (see
6.6 - 'HOW TO REGULATE THE KNIVES
WITH THE ROTOR COUNTER KNIFE')
After mounting the knives on the rotor,
ensure that all fastening bolts are tightened
with maximum care. Release of knives will
damage the machine and may cause a
serious accident.
The use of PPE (Personal Protective
E q u i p m e n t ) i s m a n d a t o r y d u r i n g
operation, maintenance and adjustment
of the machine. Wear suitable gloves
and goggles. Take special care when
handling knives and counter knife, these
components have sharp areas that can
cause injury if handled without proper
protection and care.