1) Graphic signs used in this manual
Type
Warning
Prohibition
Provision
2) Product description
I Plast 105 / 60 is a Multipurpose Electrofusion Control Unit (ECU) capable of delivering to electrofusion fittings the energy
required to carry out the fusion. This device has been designed for a professional use and controls with a frequency of 4 times
per second, that all the electrical parameters, both type: input and output, are in agreement between themselves and
coherent with those indicated by the manufacturer of electrofusion fittings. I Plast 105 / 60 / 30 works with fusion fittings like
"electrofusion" made of polyethylene, PE80, PE100, PE-X and PP. I Plast 105 / 60 / 30 can be used at ambient temperature
within the range -10; + 45 ° C. Utilization beyond these limits must be agreed in advance with our technical department.
ECU automatically sets correct fusion parameters by Scanner/Optical Pen reading or manual introduction of Bar Code visible on
the couplers (according to ISO13950 ). In case couplers do not show Bar Code, it is possible to manually introduce Voltage and
Fusion Time recommended by manufacturer.
I Plast 105 / 60 / 30 has an internal memory for storage of fusion parameters (electrical parameters, time, fittings features,
etc.). It is also possible to print out Fusion Data and download them to a PC for further processing and/or integration in proper
Data Base. Any use not mentioned in this manual is not allowed.
3) General warnings
Read all warnings and technical information carefully. Otherwise you can being involved in accidents at the workplace. Follow
all indications for health and safety at work. This manual is part of the product, Plastitalia S.p.A. cannot be call as responsible
for damages that are subsequent to the missed respect of the contents of this manual.
3.1) Workplace warnings
a) Keep the workplace clean and well lighted. Untidiness and darkness increase the possibility of accidents.
b) Do not use machine in explosive atmosphere, such as in the presence of flammable liquids, gases or dusts. Under
certain conditions, ECU may produce an electrical arc which could cause a fire.
c) Keep children and unauthorized people away.
3.2) Electric current warning
a) Electrical tools' plugs should be placed properly into the sockets. Never modify plug on this ECU. Unmodified plugs and
sockets reduce the risk of electrical shock.
b) Avoid exposing to rain and water in general ECU. Contact with water increases risk of electrical shock.
Grafic sign
Key word
Risk
Ban
Obligation
Hazard Type
How to fix
Follow safety provisions included in
Generic
this manual.
Disconnect the ECU from Voltage
Electric shock
before any operation that isn't the use
(death)
described in this manual.
Follow safety provisions included in
Serious injuries
this manual.
(death)
Follow safety provisions included in
Generic
this manual.
Use personal safety equipment. Follow
safety provisions included in this
Burn, scald
manual.
Pag. 9