14.1.2) Emergency Stop

If necessary, at any time during use you can cause an emergency stop by pressing the on / off button to the OFF
position, or by pressing the STOP button.
Having pressed the on / off button to the OFF position (in any case after disconnecting the control unit from the power
source) after the following restart you will see this message: "Warning, Error, Power interrupted before the end of the
work". Press OK button to proceed and the display shows:
Having pressed the STOP button, you will see this message: "Error, STOP command! Welding Failed ". Press the OK
button to proceed and the display shows:
14.1.3) Reset
Reset Procedure to do after pressing the on / off button in the OFF position
Unplug the fitting from the control box terminals (change or wait until the fitting is cool before another fusion
cycle; let pass the cooling time indicated on the fitting)
Press START to activate the main screen
Reset Procedure to do after pressing the STOP button
Unplug the fitting from the control box terminals (change or wait until the fitting is cool before another fusion
cycle; let pass the cooling time indicated on the fitting)
14.2) Fusion start-up
14.2.1) Automatic fusion by Bar Code reading
The display shows the highlighted icon COD:
Press the OK button and the display changes
Read the fitting bar code with the scanner