3.5.2) Fusion process control
a) The operator shall check ECU and the complete fusion process, including the cooling phase of the joint.
b) In case of smoke and/or loss of melted polyethylene stop immediately the process by pressing the red STOP button.
c) Be aware that the fusion of any material involves a risk of fire ignition. Inquire about how to alert the fire department
and/or providing a device for extinguishing of fires.
3.5.3) Safety distances during the fusion process
a) Avoid body contact with fittings or cables during fusion process. Keep a minimum safety distance of 1 meter.
4) Identification plate
On the rear part of the ECU is placed the identification plate. Following image is a template:
Data are:
type
manufacturing year and month
largest welding diameter (Plastitalia fittings)
voltage and frequency input
power max (W)
total weight
classification (conform to ISO 12176-2)
serial number (bar-code and numerical code)