Methods of fusion data transfer of the fitting to I Plast 105 / 60 / 30 are:
•
By means of barcode (ISO 13950, type 2/5i, 24 digits)
Barcode contains all the instructions of the fitting's manufacturer useful for a proper fusion. Barcode contains, among
others, the following information: manufacturer, type, diameter, voltage, fusion time (with the relative correction of
the time according to the ambient temperature) resistance and its tolerance, etc.
•
Manually by selection of Bar Code numbers
In the case of the Barcode cannot be read by the optical reader (defective scanner) it is possible to insert, either
manually, all numbers that compose it.
•
Manually by selection of fusion time and fusion voltage
Unlike what stated above, it is possible to directly insert the data relating to the fusion voltage and the fusion time
indicated on the fitting. The user must be aware that in this case ECU is unable to correct the fusion time according to
the ambient temperature.
11.2) Range of applications
I Plast 105 / 6 0 / 30 is a Multipourpose device able to weld all electrical fittings with an operating voltage (AC) between 8 and
48 V and at maximum of 50 ° C ambient temperature.
11.3) Limits
11.3.1) Operating limits
ECU(s) can operate within the following functional limitations:
Ambient T. C °(Celsius)
20
* can vary according to environmental temperature
The cooling fan, not available on the I Plast 30, has an IP55 protection degree and it can operate in dusty and humid
environments. Its operation is due to the thermal load induced by the amount of energy required for the fitting and
the ambient temperature (it does not work with medium-small diameter fittings).
11.3.2) Power
If ECU is connected to a mains voltage of 230V - 16 A, the supply circuit must be equipped with a "slow" fuse and a
RCCB device (residual current-operated protective - circuit breaker).
The power supply circuit must be provided with a protective earth circuit.
Power the device only with a quality single-phase voltage 230 V AC 50 Hz. In case of using a generator, its power must
be adapted to the diameter of the fitting to be welded, taking care to choose models with harmonic current
distortions contained within 20%. If the generator is not in double insulation, the connection to earth must be
executed in accordance with the applicable regulations and legislation applicable in the country where the ECU is in
use.
11.3.3) Extension supply cable
If necessary, use an extension cable having the following features:
Max peak current
Model of
required by the
Control Unit
fitting
120 A
I Plast 105
120 A
100 A
I Plast 60
100 A
60 A
I Plast 30
60 A
Pag. 17
Maximum fusion
Average current
time* (minutes)
65 A
330
105 A
23
40 A
330
60 A
40
15 A
60
30 A
25