The display shows the request to disconnect the fitting:
The control unit go back to the first screen for a new fusion cycle:
14.2.2) Fusion by manual introduction of Bar Code
If the automatic reading system - scanner or optical pen - is defected, the control unit will switch to manual mode.
NOTE: You can switch to manual mode in the presence of scanners working properly. In "Waiting for Scan" position
(page 19), press > button to highlight the bar code icon and then OK button.
Through the use of arrows < and > choose the option
and the display shows:
Use the choice/option buttons + and – to increase or decrease the value to be inserted as the first digit. When you
reach the required value, press the button > to move to the next digit and continuing till the inclusion of all fitting code
digits. After the last digit, press the OK button and the display shows:
WELD !
11,48
to manually enter the entire number code of fusion fitting