9
Venting Systems
F. Through The Wall
Horizontal termination cap must be a minimum of 6 inches.
(152mm) from the wall. Approved for mobile home instal-
lations. Must use 3 or 4 inch (76-102mm) "L" or "PL" listed
pellet venting or Listed double wall pipe and an authorized
Outside Air Kit in mobile homes.
Please note that while the minimum clearance for the
termination cap is 6 inches (152mm) there is the pos-
sibly of soot build-up around the termination area. If this
occurs we suggest to move the termination further away
from the house to prevent it. The suggested minimum is
12 inches.
Straight Out
45 Degree
NOTICE:
6 in.
(152mm)
Minimum
From Glass
Illustration shows venting going in both directions.
Choose which one is best for your installation.
6 in (152mm)
Minimum
In Canada, where passage through a wall or parti-
tion of combustible construction is desired, the
installation shall conform to CAN/CSA-B365
DO NOT DOWNWARD VENT.
10 in.
(254mm)
Minimum
Non-combustible Hearth Pad
6 in (152mm) Minimum
Wall
Thimble
3 in.
(76mm)
Minimum
7077-171I • December 08, 2016
CAUTION
The following will occur:
• The appliance will not vent properly
• Smoke spillage in the house
• Excessive sooting
Horizontal
Wall
Termination
Thimble
Cap
6 in.
(152mm)
Minimum
3 in. (76mm)
Minimum
31