9
Venting Systems
WARNING
Fire Risk
Inspection of Chimney:
Masonry chimney must be in good condition.
Meets minimum standard of NFPA 211
Factory-built chimney must be minimum 6 inch
(152mm) UL103 HT.
D. Masonry
E. Alternate Masonry
30
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. Refer
to the owner's information manual provided with this appli-
ance. For assistance or additional information consult a
qualified installer, service agency or your dealer.
Concrete Cap
1 in. (25mm) Clearance
with Firestop
3 in. (76mm) Minimum
6 in. (152mm)
Minimum
Non-combustible Hearth Pad
Concrete Cap
1 in. (25mm)
Clearance with Firestop
6 in.
(152mm)
Minimum
Non-combustible
Hearth Pad
7077-171I • December 08, 2016
WARNING
Fireclay flue
Liner with Airspace
Flashing
1 in. (25mm) Clearance
Sheathing
Clean-Out
Airtight
Clean-Out Door
Fireclay Flue Liner
with Airspace
Flashing
1 in. (25mm) Clearance
2 in. (5.08mm) Minimum
Sheathing
Airtight Clean-out Door