Venting Systems; Vertical - Interior - Typical Installation; Through The Wall & Vertical - External - Horizontal; Vertical Into Existing Class A Chimney - Pleasant Hearth PH35PS-B Manual Del Usuario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

9

Venting Systems

A. Vertical - Interior - Typical Installation
PREFERRED METHOD #1
Flashing
Firestop
6 in.
(152mm)
Min.
Non-combustible Hearth Pad
B. Through The Wall & Vertical - External -
Horizontal
PREFERRED METHOD #2
2 in. (5.08 mm) Minimum
6 in. (152 mm)
Minimum
Non-combustible Hearth Pad
NOTICE: These are guidelines for successful venting of your pellet appliance. The more vertical rise you can obtain in
your system, the better it will perform. Horizontal vent runs can accumulate ash and will need to be cleaned
more often. Try to keep them as short as possible.
Rain Cap
12 in.
(305mm)
Minimum
follow pipe manufacture
listed clearance
Clean-out T
Rain Cap
12 in.
Flashing
(305mm)
Minimum
Support
Bracket
Every 60 in.
(1.5 m)
Wall Thimble
Tee
Clean-out Cover
7077-801D • September 17, 2019
C. Vertical into Existing Class A Chimney
Flashing
Firestop
Ceiling Support
6 in.
(152mm)
Min.
Non-combustible Hearth Pad
We strongly recommend a minimum of 60 inches
(1.5m) vertical, however above the eave is preferred.
Both installations are approved for mobile home
installations. Must use 3 or 4 inch (76 to 102mm) "L" or
"PL" Listed pellet venting or Listed double wall pipe and
authorized Outside Air Kit in mobile homes. Single wall
pipe is approved for residential installations only.
Air Clearance to Pipe:
This appliance was tested with standard 3 inch (76mm)
Listed pellet vent.
Pellet pipe manufacturers Listed reduced clearance pipe
may be use for reduce clearance from 3 inch (76mm) air
clearance to no less than 1 inch (25mm) air clearance to
combustibles for approved Listed pellet pipe.
Follow pipe manufactures listed air clearances to
combustibles and installation instructions for all
reduced air clearances installations.
Rain Cap
12 in. (305mm) Minimum
6 in. (152mm) Class A
Chimney Connector
Adapter
Follow vent manufacturer's
clearances for reduced clearances
6 in. (152mm) Flue
Connector
follow pipe manufacture
listed clearance
Clean-out T
29
Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Ph50ps-bPh50cabps-b

Tabla de contenido