⅝
27
27 ¼" (692mm)
36" (914mm)
min. to
combustibles
36" & 48" Low Back Guard
30" Low Back Guard
Max 36 ¾"
(933mm)
⅞
Min 35
"
Front Face
(911mm)
Note:
With the oven door fully open, the top of the
door extends to 44 ⅞" (1140mm) from the
back wall, behind the range when installed.
Installation must allow ample clearance for
movement around the door when fully
opened.
English 6
Combustible
Materials
" (702mm)
10
"
¾
(273mm)
2 ¼"
(57mm)
High Shelf
(559mm)
(229mm)
6"
(152mm)
⅝
24
"
(625mm)
24" max.
(606mm)
Back Wall
24 ¾"
(629mm)
23"
(584mm)
22"
9"
Installation with Flush Island Trim
36" (914 mm)
min. to
combustibles
Flush Island Trim
13
" (21mm) height
/
16
Max 36 ¾"
(933mm)
Front Face
⅞
Min 35
"
(911mm)
as defined in the "National Fuel Gas
Code" (ANSI Z223.1, Current Edition).
Clearances from non-combustible materi-
als are not part of the ANSI Z21.1 scope
and are not certified by CSA. Clearances
of less than 12" (305 mm) must be
approved by the local codes and/or by
the local authority having jurisdiction.
Combustible
Note: For Flush Island
Materials
Trim installations,
counter surface should
have a cantilever edge
meeting the back section
of the Flush Island Trim
accessory.
12" (305mm) min
to combustible
surface with Flush
Island Trim
Cantilever
Note: If an inner wall is
used under the cantilever
counter top, there should
⅛
be a
" (3mm) gap from
the rear of the range to the
inner wall.
Figure 2: