1. Prepare holes at fastener locations as identified below:
•
For walls, wall studs, or floors composed of solid
wood or metal, drill 1/8" (3mm) pilot holes.
•
For walls or floors composed of drywall, sheet-rock
or other soft materials, drill 3/16" (5mm) holes to a
minimum depth of 1¾" (45mm), then tap plastic
anchors into each of the holes using a hammer.
•
For walls or floors composed of concrete or
concrete block, drill 3/16" (5mm) holes to a
minimum depth of 1¾" (45mm), then tap concrete
anchors into each of the holes using a hammer.
•
For walls or floors having ceramic tile covering, drill
3/16" (5mm) holes through the tile only, then drill
into the material behind the tile as indicated
immediately above.
Left
Cabinet
Mounting Anti-Tip Bracket
The floor mounted bracket shall be installed as follows:
1. Place bracket on floor in position shown in Figure 8.
•
Bracket may be used in either corner of the
installation area.
2. Secure to floor and wall stud using the (4) 1½" (38mm)
Phillips head screws provided.
3. Later, when the unit is installed, the adjustable leg will
slide under the bracket, as shown in Figure 7.
4. If the range is moved to a new location, the Anti-Tip
Device must be removed and reinstalled.
English 12
Wall Line
Front edge
X
of right
typical—
cabinet
either side
Range leg will
slide into bracket
slot after installation.
Right
Cabinet
X = 4½" (114mm) [for 30" range]
X = 6¾" (171mm) [for 36" range]
X = 4½" (116mm) [for 48" range, right side]
X = 3¼" (83mm) [for 48" range, left side]
Figure 8: Placement of Anti-Tip Bracket (Top View)
Figure 7: Anti-tip Bracket
From Edge
X
of Range