Troubleshooting

In case of malfunction, lack of heating, steam release when drawing hot water, turn power off and contact the
installer.
Troubleshooting operations must be performed exclusively by a professional.
4.1.

Other Malfunctions

Problem
No more heating
No hot water
Water not hot enough
Insufficient amount of hot water
Réf doc : U0570659_#
Installation
Operation
A
B
Key
B
Protection
Possible cause
No power supply to the water heater:
fuse, wiring...
The main power supply to the water
heater is not continuous.
Temperature setpoint is too low.
The heating element or its wiring is
partially faulty.
Undersized water heater
Maintenance and
Troubleshooting
III
C
Name
Warranty
Key
Name
C
Flange
Diagnostics and troubleshooting
Check voltage on power wires
Check settings of the installation
(see operating ranges)
Check if the power to the unit is
continuous.
Check if absence of cold water
supply on the hot water circuit
(Possible faulty thermostatic mixing
valve).
Set the temperature setpoint higher.
Check the resistance of the spark
plug on the spark plug connector
and its condition.
Check the safety thermostat.