Product Overview
Before
filling,
the
heater must be leveled by
wedging it if necessary.
The nameplate located on
the right of the cover must
be accessible at all times.
The installation site must comply with protection rating IP X1B, in accordance with NFC 15-100 requirements.
Maintain a clearance of 500 mm in front of the electrical part of the device and 300 mm in front of the
hydraulic part to maintain access for periodic maintenance.
The floor must be able to support a load of 400 kg minimum (area underneath the heater).
Failure to follow installation requirements can lead to lack of performance of the system.
4.2.

Installation

Unheated room with a temperature over 5°C and isolated from house heated rooms.
Recommended location = underground or half below ground, room with a temperature above 10°C throughout
the year.
Examples of location:
Garage
Utility room
Half-below-ground room
Réf doc : U0570659_#
Installation
water
The water heater must be installed on a smooth, horizontal
surface.
Maintenance and
Operation
Troubleshooting
Minimum height from floor to ceiling
required to lift the product:
Warranty
150 L : 1175 mm
200 L : 1395 mm
295 L : 1850 mm