3.

Handling

The product includes several handles to facilitate carrying to the installation site.
Tilt the product backward for handling with a hand trolley, for example.
To transport the water heater to the installation site, use lower and upper handles.
Follow transporting and handling requirements indicated on the packaging label of the water heater.
4.

Product Setup

4.1.

Requirements

A drain pan must be installed under the water heater when installed above inhabited dwellings.
Depending on the models, the water heaters can be wall mounted or placed on the floor.
The wall-hung vertical models are fitted with brackets allowing direct fastening to 4 bolts to be secured on the wall.
In upright position, if the wall cannot support the weight of the device filled with water, put it on a tripod (optional) and
secure it to the wall using the top bracket.
Leave a clearance of 500 mm below the protective cover (see diagram below) to allow access for equipment
maintenance or possible disassembly.
A drain connected to the sewer is required at the outlet of the safety unit.