Product Overview
4.
Operating Principles
4.1.
Winter Operation (boiler in use)
Your boiler is in use and ensures heating of the sanitary water by hot fluid circulating inside a heat exchanger.
4.2.
Summer, Spring or Fall Operation (the boiler is off)
For operation with an electric kit (not factory supplied)
Your boiler is turned off. Heating is provided through the power supply to the electrical resistance. The thermostat
interrupts the power supply when the water temperature reaches 65°C.
5.
Electrical Systems
There are three possible electrical systems for each Water heater type:
- Water heater equipped with a thermostat only (without electric booster pump). Standard on all models.
- Water heater equipped with a single-phase electric kit
- Water heater equipped with a three-phase electric kit
6.
Technical Specifications
Capacity
Primary
(L)
Pressure
75
100
150
200
150
200
295
*
Rated power given in kW for a primary output of 2 m
**
Maximum output for the first hour, with a storage at 60°C in the tank.
***
Minimal consumption in kWh per 24 hours for a storage at 65°C and an ambient temperature of 20°C.
Technical specifications in compliance with the standard: EN 60335
These values may vary depending on the season, cold water temperatures and the temperature of
the installation location, excluding recycling.
Réf doc : U0570659_#
Installation
Max.
Hourly
Exchanger
output
Power kW*
Liters**
(bar)
Wall-hung Exchangers Tanks
10
19,3
10
19,3
10
25,6
10
25,6
Exchangers Tanks On Stand
10
30
10
43,2
10
49
3
/H at 90°C and a secondary output at 45°C (delta T = 35°C).
Maintenance and
Operation
Troubleshooting
Min. Pre-heating
Output
Time (delta T)
per 10
min.
55 °C
476
121
22
476
162
30
631
242
35
631
272
46
740
244
29
1064
326
28
1230
489
38
Warranty
Minimal
Consumption
kWh/24 h***
30 °C
9
1,12
13
0,94
15
1,04
24
1,33
12
1,19
12
1,31
15
1,57
Page 11/ 220