8.1 GENERAL INFORMATION
Boiler cleaning is very important to prevent: poor combustion, deposits of ash
and unburnt products in the brazier, as well as thermal efficiency.
Cleaning operations for all parts must be carried out with the boiler
unplugged and cold.
Clean the brazier regularly at every lighting and/or pellet reloading.
Dispose of cleaning waste in accordance with the current local regulations.
8.2 CLEANING TABLE
Given below are the control and/or maintenance operations for correct boiler use and
operation.
Part
Brazier
Ash compartment - box
Heating chamber tube bundle
Manifold - fume extractor
Ash - fire door seal
Pipe - flue connection
♦
= routine operation that can be carried out by the user /
The door seals must be checked periodically to prevent air from entering
and ensure combustion chamber low pressure.
8.3 CLEANING OPERATIONS
8.3.1. CLEANING THE BRAZIER - BRAZIER HOLDER
Clean the brazier as follows:
Step
Action
1
Remove the brazier.
Remove the ash deposited in the combustion chamber and brazier holder.
2
Note: a suitable vacuum cleaner may be used.
This operation must be carried out daily to ensure perfect combustion
conditions, since the brazier holes allow the flow of combustion air.
Also make sure the secondary air holes in the side pipes of the brazier holder are free of any
combustion residuals and ash.
When necessary, clean the fire door glass for visually checking the flame inside the
combustion chamber.