NATURFIRE EVO 27 - 34
▪
Occurs if the fume
probe detects a fume
AL 3
temperature above 280°C.
HOT FUMES
▪
The shutdown procedure
is activated.
▪
Occurs when the fume
AL 4
extraction fan is faulty.
FAN FAIL
▪
The shutdown procedure
is activated.
▪
No flame in ignition stage.
AL 5
▪
The shutdown procedure
NO IGNITION
is activated.
AL 6
Brazier not fed with pellets.
NO PELLETS
▪
Occurs in case of
AL 7
cutting in of the auger
THERMAL
duct temperature safety
SAF
thermostat.
▪
The system is stopped.
▪
In the work stage the
AL 8
stove detects a pressure
NO NEG
below the vacuum switch
setting threshold.
PRESS
▪
The system is stopped.
AL 9
Appears when the
INSUFF
combustion air flow is below a
certain threshold.
DRAUGHT
▪
Occurs when the water
AL E
pressure does not come
WATER
within the values for
PRESSURE
correct operation.
▪
The system is stopped.
▪
Occurs in case of cutting
in heating chamber
AL A
water temperature safety
SAFETY H
O
thermostat with T>95°C.
2
▪
The system is stopped.
EN
▪
Too many pellets.
▪
Reduced heat exchange
in the system.
▪
The fume fan is blocked.
▪
Faulty speed control
sensor.
▪
No power to fume fan.
▪
The pellet hopper is
empty.
▪
The heater is faulty,
dirty or not correctly
positioned.
▪
Pellet load setting
incorrect.
▪
The pellet hopper is
empty.
▪
The pellet loading
gearmotor has to adjust.
▪
The gearmotor does not
load pellets.
The safety thermostat has
detected a temperature
above the setting threshold
due to overheating of
the bottom part of the
hopper blocking gearmotor
operation.
▪
The combustion chamber
is dirty.
▪
The fume duct is
obstructed.
▪
The fire door is not closed.
▪
The overpressure valves
are open-stuck.
▪
Faulty vacuum switch.
▪
The combustion chamber
is dirty.
▪
The fume duct is
obstructed.
▪
The fire door is not
closed.
▪
The overpressure valves
are open-stuck.
▪
Faulty air flow meter.
Occurs when the pressure
transducer on the water
circuit detects a pressure
below or above the fixed
limits.
The safety thermostat has
detected a temperature above
the setting threshold due to
overheating of the heating
chamber water blocking
gearmotor operation.
cod.48427M013_11/19
▪
Adjust the pellet flow.
▪
Other reinstatement operations
must be carried out by a
Service Centre.
Reinstatement operations must be
carried out by a Service Centre.
▪
Check pellets in hopper.
▪
Check the lighting procedures.
▪
Other reinstatement operations
must be carried out by a
Service Centre.
▪
Check pellets in hopper.
▪
Adjust the pellet flow.
▪
Other reinstatement operations
must be carried out by a
Service Centre.
▪
Check the cause of excessive
overheating.
▪
Reset the safety thermostat by
pressing the reset button.
▪
Check cleanness of the fume
duct and combustion chamber.
▪
Check hermetic closing of
the door.
▪
Check closing of the
overpressure valves.
▪
Other reinstatement operations
must be carried out by a
Service Centre.
▪
Check cleanness of the fume
duct and combustion chamber.
▪
Check hermetic closing of
the door.
▪
Check closing of the
overpressure valves.
▪
Other reinstatement operations
must be carried out by a
Service Centre.
Check the cause of the problem,
restoring the circuit pressure by
bringing it to the normal operating
value.
▪
Check the cause of excessive
overheating.
▪
Reset the relevant safety
thermostat by pressing the
reset button.
87