Status
OFF
START - PREHEATING
PELLET PRELOAD
AWAITING FLAME
PELLET LOADING
FIRE PRESENT
WORK
WORK MODULATE
BRAZIER CLEANING
FINAL CLEANING
After a certain time has elapsed, if the fume temperature has not reached the permissible
minimum value the boiler goes in alarm status.
Do not use flammable liquids to light the unit.
In case of persistent failed lighting, contact the Service Centre.

7.5 WORK STAGE

After the "STARTUP" stage, the boiler goes to the "WORK" mode which is the normal operation
mode. The user can adjust the heating power from the max. value of 5 to a min. of 1 with the
buttons "P6" and "P5".
DHW circuit function activation "ON" is displayed by the segment/LED (A).
Clock
H
O temperature
2
Boiler - Puffer
Dialogue box
Make sure to check the pellet level in the hopper so that the flame does not
go out due to lack of pellets.
The pellet hopper lid must always remain closed; it must only be opened
when loading fuel.
During the work stage, the operations described in the following paragraphs can be performed.
80
NATURFIRE EVO 27 - 34
igniter
flue extraction
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
cod.48427M013_11/19
Devices
auger
OFF
OFF
ON
OFF
ON
ON
ON
ON
ON
OFF
Water temperature (A)
Button P6
Button P5
Power set to 3
Real power in
work equal to 1 -
flashing
exchanger
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
-