8.5
To empty the spent mandrel container
•
The spent mandrel container (I) must be emptied in good time; overfilling will cause the
blind rivet setting tool to malfunction.
•
Unscrew the spent mandrel container (I) by turning anticlockwise, collect spent mandrels
in suitable container.
•
Screw on spent mandrel container (I).
9.
Maintenance and care
The complete grip mechanism must be maintained regularly.
9.1
To oil jaws
•
Disconnect the blind rivet setting tool from the compressed air supply.
•
Unscrew steel head sleeve (B).
•
Dip the complete jaw mechanism up to the O-ring (C) into an oil batch or wet jaws (E)
with oil and allow to drip off.
•
Reassemble in reverse order.
9.2
To change jaws
•
Disconnect the blind rivet setting tool from the compressed air supply.
•
Unscrew steel head sleeve (B).
•
Unscrew jaw housing (D).
•
Remove jaws (E).
•
Clean jaw housing (D) and grease sliding surfaces.
•
Fit new jaws (E) from the front (they are held by the grease).
•
Reassemble in reverse order, ensuring that all parts are fixed tight.
9.3
To top up hydraulic oil
Follow correct sequence!
Wear safety goggles!
•
Store the riveting tool in a dry place.
•
If necessary, worn nosepieces (A) must be replaced as per section 8.2.
•
After prolonged use, it may be necessary to refill or replace hydraulic oil. Follow the steps
below to refil or replace hydraulic oil.
Danger of oil escaping at high pressure.
GB
21