TECHNICAL FEATURES OF THE UNIT:
Power
Maximum actuator power
Maximum flashing light power
Max current accessories, 24 V
Gate open indicator
Working time
Pause time
Courtesy light time
Force adjustment
Operating temperature
Nice s.r.l. reserves the right to modify its products at any time without prior notice.
FINAL NOTES:
This manual is for use only by technical personnel qualified to carry out the installation.
•
No information given in this manual can be considered of any interest to the end user!
•
No settings or adjustments contained in this manual can be carried out by the end user!
Once the plant is finished inform the end user, in detail also in writing, how to use the automatic gate, about residual
hazards and about how to use the manual unlock device in the event of a power cut.
Inform the owner of the plant about the need for a regular and accurate maintenance, especially regarding a regular
check of the safety and torque limiting devices.
18
: 230 Vac ±20% , 50 Hz
: one
/
Hp motor with capacity, max 20 µF
1
2
: 100 W at 230 Vac (the output has a fixed voltage)
: 100 mA
: 24 V maximum 3W (only on ROBO)
: from 2 to 120 Sec.
: from 2 to 120 Sec.
: approx. 40 Sec.
: selectable 30,45,60,80 or 100%
: -20 to 70 °C