What To Do If; Technical Specifications - Nice ROBO RO 300 Manual De Instrucciones

Motorreductor electromecánico para cancelas correderas
Ocultar thumbs Ver también para ROBO RO 300:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 64

11) What to do if ....

This section will help fitters to solve some of the most common
problems that may arise during installation.
No LED is on:
• Check whether the control unit is powered (check mains voltage
is present at terminals 1-2 and a voltage of approx. 24Vac at
terminals 5-6).
• Check the 2 mains fuses have not blown; if none of the Led's is
on a serious fault has probably occurred and the control unit
should therefore be replaced.
The OK LED flashes regularly but the INPUT Led's do not
reflect the state of the respective inputs
• Carefully check the connections on input terminals 7-13.

12) Technical specifications

Mains power input
Versions /V1
Max. current for 24V services
Flashing lamp output
Gate open indicator output "SCA"
Operating temperature
Working Time on ROBO/THOR
Working Time on OTTO
Pause Time
On the PIU card
Partial opening time ROBO/THOR
Partial opening time OTTO
Courtesy light time
The manoeuvre does not start
• Check that the Led's of the "Stop" (FCA + FCC), "Photo" and
"Photo2", if installed, safety device are on and that the relative
command Led that is activated ("Step-By-Step", "Open" or
"Close") remains on for the whole duration of the command.
The gate changes direction during a manoeuvre
An inversion is caused by:
• The photocells triggering ("Photo2" during the opening
manoeuvre, or "Photo" during the closing manoeuvre); in this
case, check the connections of the photocells and check the
input Led's.
: 230 Vac 50/60 Hz
: 120 Vac 50/60 Hz
: 200mA
: For flashing lamps at mains voltage, maximum power 40 W
: For indicator lamps at 24 Vac, maximum power 2 W
: -20 ÷ 70 °C
: Adjustable from 2.5 to >60 s, or from <50 a to >120 s with TLM
: Adjustable from 2.5 to >20 s, or from <20 to >40 s with TLM
: Adjustable from 5 to > 160 s.
: Adjustable from 1 to > 30 s.
: Adjustable from 1 to > 14 s.
: Adjustable from 1 to > 180 s.
GB
15
Tabla de contenido
loading

Este manual también es adecuado para:

Robo ro 1000Robo ro 1010Robo ro 1040Robo ro 1124

Tabla de contenido