User manual
Compressed air system:
• Hydraulic oil, vaseline, brake fluid, petrol and other liquids must never be allowed to enter the compressed air system.
• Equip the compressed air system with a filter regulator, dryer, and lubricator.
If you wish to lubricate the compressed air circuit, we recommend you use one of these types of hydraulic oil: AGIP OSO 100, MOBIL DTE 27, ESSO
TERESSO 100, SHELL TELLUS 100 or BP ENERGOL HP 100.
1. Maintenance must be carried out by qualified personnel.
2. If repairs are required on the pneumatic system, they must be carried out under the supervision of our after-sales department in France,
otherwise, please refer to the warranty conditions.
3. No modification should be made that might affect the conformity of the jack.
TROUBLESHOOTING
The table below shows the possible problems that may occur when using the jack. If a problem occurs that is not listed in the table below, stop using
the unit and refer to the «Shutdown» procedure. Then contact your distributor to discuss how to proceed.
TROUBLESHOOTING
The control is activated but the jack does not lift.
Air leak during lifting.
The product lowers by itself when the control handle is in its
starting position.
The product stops while descending.
DEACTIVATION
If the product appears to be damaged in any way, does not operate normally, or is missing any parts, it must be taken out of service immediately by
removing the air coupling on the jack inlet. Do not use the unit if you notice parts are broken, bent or cracked.
STARTING THE DEVICE
The jack must be disposed of in accordance with the current environmental and disposal directives of the country in which it is located.
WARRANTY CONDITIONS
The warranty covers any defect or manufacturing defect for 2 years from the date of purchase (parts and labor). The warranty does not cover
incidents due to misuse, dropping, disassembly, or any damage caused during transit. The warranty does not cover normal wear and tear of parts if
maintenance is not kept up to date. Only spare parts supplied by the manufacturer may be used to repair the jack. The maximum load specifications
are shown on the label affixed to the jack. The user must not remove, soil, or damage this label. The warranty is automatically invalidated if this label
is falsified. Contact the retailer or manufacturer to get new ones if needed.
In the event of a malfunction, return the unit to your distributor, enclosing:
- A dated proof of purchase (receipt, invoice, etc.) and a note explaining the fault.
10
Translation of the original
instructions
Excessive load.
Insufficient air pressure for the load.
The safety valve is open.
Air pressure too high.
Check that there are no punctures in
the air cushion.
Pneumatic circuit leak.
There may be something under the
vehicle.
CAUSES
Check that the weight of the vehicle
is below the maximum capacity of the
jack.
Check that the air intake is between 7
and 8 bar.
Make sure the air hose is not pinched.
Reduce inlet air pressure (8 bar max).
Adjust the air pressure (8 bar max).
Replace the air cushion under GYS
Aftersales service guidance.
Contact your distributor.
Remove any objects.
AIR JACK
SOLUTIONS