AFTER SOME TIME OF
OPERATION, IT INDICATES
CHANGES IN AIR LEVEL
AND PELLETS STACK IN
THE BASKET.
DOOR OPEN OR ERROR IN
DEPRESSION.
PUMP DISCONNECTED.
EXTRACTION
MOTOR
DISCONNECTED.
ENDLESS
MOTOR
DISCONNECTED.
ELECTRODE
(START-UP
RESISTANCE)
DISCONNECTED.
SHORT-CIRCUIT
IN
THE
PUMP.
SHORT-CIRCUIT OF THE
EXTRACTION MOTOR.
 The boiler needs air for combustion.
 Check the Lumber of hours of operation
since last maintenance (Menu 2-5).
 Check pellets quality.
 As indicated, the fireplace door is open or
there is a failure in the air Redding system
necessary for combustion to happen.
 The C.P.U. does not detect the pump.
 The C.P.U. does not detect the Extractor.
 The C.P.U. does not detect the reduction
motor of the Endless motor.
 The C.P.U. does not detect the start-up
Electrode (start-up resistance).
 The Unicontril detects that the pump or the
output voltage of the C.P.U. corresponding
to the pump is in short-circuit.
 The C.P.U. detects that the Extractor of
tension outlet of the C.P.U. corresponding to
the extractor is in short-circuit.
 Make sure fireplace door and ashtray basket
are well closed.
 Carry out maintenance.
 Replace the bag of pellets by another bag;
make sure it is stored in a dry place.
 Fire place door open. Close the door.
 Gas outlet pipe stacked. Clean gas outlet.
 Boiler
full
maintenance.
 Air entrance pipe stacked. Clean air Entrance
pipe.
 Air reading pipe (transparent silicone pipe
linking the C.P.U. to the air inlet pipe),
disconnected or cut. Connect or replace.
 Extractor does not turn.
 Failure in depression reading system of the
C.P.U., check depression air level, cf. Menu
3, chapter 1 (S.A.T.)
 If the boiler is new, this might be due to
electric power problems.
 Check the pump is connected to power
through menu 3 section 0.
 Check the grey cable going out from the
C.P.U. Connect it if necessary.
 If the boiler is new, this might be due to
electric power problems.
 Check is power is being supplied to the
exhaust motor through menu 3 section 1.
 Check the red cable going out from the
C.P.U. Connect it if necessary.
 If the boiler is new, this may be due to
electrical problems.
 Check if the endless motor is connected to
power, see menu 3 section 2.
 If power does not reach the endless motor,
check-with the boiler disconnected- if the
safety thermostat is activated. Reactivate if
necessary.
 If the boiler is new, this might be caused by
electrical problems.
 Make sure power reaches the start-up
resistance, see menu 3 section 3.
 Check the black cable going out from the
C.P.U. Connect it if necessary.
 If the boiler is new, this might be caused by
electrical problems.
 Check with a multimeter if the motor is
clamped to earth or the winding is in short-
circuit. Make sure power reaches the
convection motor, see menu 3 section 0.
 Check the grey cable going out from the
C.P.U. Connect it if necessary.
 If the boiler is new, this might be caused by
electrical problems.
 Check with a multimeter if the motor is
clamped to earth or the winding is in short-
circuit.Make
convection motor, see menu 3 section 1.
 Check the red cable going out from the
C.P.U. Connect it if necessary.
43
of
ash
inside.
Carry
sure
power
reaches
out
the