4.17. The air input pipe should not be drained with the risk of affecting the correct operation of the boiler. For this
reason, and in order to facilitate fresh air input, it is necessary to set up a ventilation grid AT NOT LESS than
50cm both horizontally and vertically from gas output, see point 4.11.
Direct air currents shall also be avoided as they might prevent a correct operation of the boiler and as a
consequence, heat performance.
4.18. In any case the design of the chimney termination will impede the free diffusion in the atmosphere of
combustion products. A metallic mesh with a gap of 3x3 cm can be placed to avoid the entry of birds or
unwanted objects.
COMPLIANCE WITH THESE NORMS ARE OUT OF ECOFOREST'S CONTROL; ECOFOREST DOES NOT BEAR THE
RESPONSIBILITY FOR ANY RESULTING DAMAGE.
WE RECOMMEND THAT A CONFIRMED SPECIALIST SETS UP YOUR PELLETS BOILER.
4.19. Check the space between the boiler, the fuel, and any flammable material, check drawing 3.
4.20. Do not install the boiler in a sleeping room.
4.21. The power cable provided by ECOFOREST is 1.4m long; you might need a longer one. Always use a cable with
ground plug.
FREE SPACES AND MINIMUM DISTANCES WITH FLAMMABLE MATERIAL.
Security distances should be respected when the boiler is installed in spaces where materials, either
construction materials or those surrounding the boiler, are likely to be flammable.
4.22. If the floor is made of a combustible material, install a fire protection between the floor and the boiler.
A
Lateral wall.
B
Back of the boiler.
C
Total depth with doors open.
D
Shelf.
E
Depth of boiler.
Although we cannot keep track of or describe every single installation, option, or the local installation
regulations corresponding to your area, Ecoforest guarantees that the installations suggested below will enable
your boiler to function properly, and to conform to minimum personal and material safety measures.
If you are installing your boiler in a building, in addition to respect local regulations on gas flues, you
should consult with the residents' association to avoid future problems.
Please read the entire manual carefully, especially the chapter on installation to ensure your boiler
operates properly and at full power.
LOCATION AND SAFETY DISTANCES.
≥ E
≥ 80 mm
See dimensions
≥ 400 mm
See dimensions
EXAMPLES OF FLUE INSTALLATIONS.
32
Drawing 3