To carry out this operation, proceed as follows.
1 - Turn off the gas supply tap
2 - Pull off the knob (A).
3 - Undo the screws (C) and remove the control
panels (B).
4 - Remove the injector (D) and replace it with the
one suitable for the type of gas in use (see table
at back of manual). After making the setting,
seal the screw with paint.
5 - Replace the control panels (B) and the knobs
(A) on completion of the operation.
ADJUSTING GAS VALVE MINIMUM SETTING (OVEN)
Important
This adjustment is only required if the
type of gas to be connected is different
from that used for testing after the conver-
sion procedure has been carried out (see
page 18). Before making this adjustment,
check that the gas supply pressure is the
IT
same as the rated pressure for the type of
gas in use (see table at back of manual).
GB
To carry out this operation, proceed as follows.
1 - Turn off the gas supply tap
DE
2 - Pull off the knob (A).
3 - Undo the screws (C) and remove the control
FR
panels (B).
4 - Remove the injector (D) and replace it with the
one suitable for the type of gas in use (see table
ES
at back of manual). After making the setting,
seal the screw with paint.
5 - Replace the control panels (B) and the knobs
(A) on completion of the operation.
English
C
A
C
B
C
A
C
B
- 20 -
D
IDM-39610801400.tif
D
IDM-39611401000.tif