DISPLAYING
Err5
The display shows
Err6
The display shows
Err7
The display shows
Err8
The display shows
Err9
The display shows
Er11
The display shows
Er12
The display shows
Er13
The display shows
Er14
The display shows
Er15
The display shows
tiM
The display shows
SCEn
The display shows
- 84 - ENGLISH
DESCRIPTION
When a start command is given, the barrier
does not open.
It means that the test of the safety edges
failed.
When a start command is given, the
barrier does not rise. It means that the
measurement circuit test has failed of the
motor current.
Encoder error
When executing a self-learning function the
control is refused.
It means that the setting of the control
unit is not compatible with the requested
function
It means that programming was locked by
means of the programming lock key CL1+
(code 161213).
When a start command is given, the barrier
does not rise. It means that motor thermal
protection has intervened.
During manoeuvre, the barrier stops. It
means the control electronics of the motor
have reached too high a temperature and
proceeding with the manoeuvre could
cause serious risk for the intactness of the
components.
The self-diagnosis circuit has detected a
malfunction that prevents the safe operation
of the automation
The self-diagnosis circuit has detected an
error in the configuration parameter table
The duty cycle limit has been exceeded
When a start command is given, the
barrier does not rise. It means a timer was
programmed inside the control unit, which
prevents barrier enabling at that time.
When a start command is given, the barrier
does not rise. It means an App-controlled
situation is in progress.
SOLUTION
1. Make sure that the menu relative to the test of the facets
Co.tE
for cables (
) is configured correctly.
2. Make sure that the safety edges enabled by menu are
actually installed.
3. Check the safety edges are correctly connected as
indicated in chapter 5.6.
Contact the V2 technical assistance service to send the
control unit for repair
Check the connection of the encoder
Check the Start inputs are enabled in standard mode
Strt
StAn
(
menu set on
)
To change the settings it is necessary to insert in the
connector of the ADI interface the same key used to
activate the programming lock, and unlock the device.
Wait for the motor to cool.
The control unit will start working again when the circuit has
cooled.
Contact the V2 technical assistance service to send the
control unit for repair
Enter the configuration menu, carefully check all the
parameters and correct any errors. If the error persists,
contact the V2 technical assistance service to send the
control unit for repair
The control unit will return to normal operation after a forced
pause.
In this situation it is still possible to activate the automation
in EMERGENCY DEAD MAN OPERATION mode
(chapter 11)
Wait for the control unit to become available again.
Wait for the control unit to be available again, or shut-off
execution of the App situation.