1.4 - EU DECLARATION OF CONFORMITY
AND DECLARATION OF INCORPORATION OF
PARTLY COMPLETED MACHINE
Declaration in accordance with Directives: 2014/35/UE
(LVD); 2014/30/UE (EMC); 2006/42/CE (MD) ANNEX II,
PART B
The manufacturer V2 S.p.A., headquarters in
Corso Principi di Piemonte 65, 12035, Racconigi (CN), Italy
Under its sole responsibility hereby declares that:
the partly completed machinery model(s): NUUR4, NUUR6
Description: electromechanical actuator for barriers
• is intended to be installed to create a machine according to the
provisions of the Directive 2006/42/EC. The machinery must not
be put into service until the final machinery into which it has to be
incorporated has been declared in conformity with the provisions
of the Directive 2006/42/EC (annex II-A).
• is compliant with the applicable essential safety requirements of
the following Directives:
Machinery Directive 2006/42/EC (annex I, chapter 1)
Low Voltage Directive 2014/35/EU
Electromagnetic Compatibility Directive 2014/30/EU
Directive RoHS3 2015/863/EU
Furthermore, the product complies with the following standards:
EN IEC 61000-6-2:2019, EN IEC 61000-6-3:2021
EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A2:2019 +
A14:2019 + A15:2021, EN 62233:2008, EN 60335-2-103:2015
The relevant technical documentation is available at the national
authorities' request after justifiable request to: V2 S.p.A.
Corso Principi di Piemonte 65, 12035, Racconigi (CN), Italy
The person empowered to draw up the declaration and to provide
the technical documentation:
Roberto Rossi
Legal representative of V2 S.p.A.
Racconigi, 01/03/2023
2 - PRODUCT DESCRIPTION AND
INTENDED USE
NUUR are electromechanical road barrier mechanisms for residential,
public and industrial use, which control the opening and closing of a
driveway.
These barriers are equipped with an electromechanical gearmotor
with a 24 V motor.
The barriers work on electricity and in case of a power outage
(blackout), the boom can be unlocked manually and moved by hand.
Alternatively, it is possible to use the back-up battery (model 161261
- optional accessory) which ensures that certain manoeuvres can be
carried out in the first few hours of a power outage.
The barriers must be combined with the available booms, individually
or in pairs, to reach the desired length. Various optional accessories
are available, depending on the chosen boom, as shown
in the table.
INSTALLABLE ACCESSORIES
Cubicle
NUUR4
Boom
4 m
Rubber
Lights
Jointed boom
Aluminium skirt
2 pz
Mobile support
1 pz
Important notes for using the manual:
• throughout this manual, the term "boom gate" refers to the three
products "NUUR4" and "NUUR6"
• the accessories mentioned in the manual are optional.
m
Any use of the product other than the intended use
described is not allowed!
2.1 - TECHNICAL CHARACTERISTICS
NUUR4
Power supply
230 V~ 50 Hz
Motor power supply
24 Vdc
Maximum power
300W
Power in stand-by *
3,5W
Opening time
3 ÷ 4 s
80 %
(300 cicli ora max.)
Operative intermittence
> 4s pause
between each cycle
12W on Z1-Z2-Z3 terminals
12W on Z4-Z5-Z6 terminals
ATTENTION: any consumption of
Maximum load on
the RGB LEDs and / or traffic lights
24 Vdc attachments
connected to the optional SYNCLUX
module must be subtracted from this load
(refer to the SYNCLUX manual)
Operating temperature
-20 ÷ +55 °C
Protection degree
IP54
Weight
44 Kg
* If the ENERGY SAVING mode is activated
En.SA
Si
(parameter
=
) the power at rest is 0.4W.
NUUR6
5 m
3+3 m
-
-
2 pz
2 pz
1 pz
1 pz
NUUR6
240W
3,5W
5 ÷ 6 s
80 %
(200 cicli ora max.)
> 6s pause
between each cycle
52 Kg