Dometic GROUP WAECO AirConServiceCenter ASC5000 Instrucciones De Uso página 118

Estación de mantenimiento de aire acondicionado
Ocultar thumbs Ver también para WAECO AirConServiceCenter ASC5000:
Idiomas disponibles
  • ES

Idiomas disponibles

Service tasks
4. Lower the control panel and screw it down.
5. Close the control panel and reconnect power plug.
6. Switch on the unit and follow the instructions on the display.
NOTE
I
When you switch it on again, the values should be copied from the flash
memory card to the unit. To do this, switch to "Other selections" - "Service"
and enter the password "1518". Press ENTER to confirm the following dis-
play messages.
9.11 Changing the drained oil receptacle
NOTE
I
 Replace the drained oil receptacle and the O-ring in the lid every
6 months.
 If the drained oil receptacle has been damaged, replace it immediately.
The drained oil receptacle (20) is also leak-proof when there is a vacuum
or overpressure. A safety valve guarantees safe operation.
The drained oil receptacle must be changed every 6 months.
1. Open the cover flap (21) on the left side and remove the drained oil
receptacle (20) from the snap lock:
21
118
AirConServiceCenter
20
EN
loading

Este manual también es adecuado para:

8885200102