Service Tasks; Leak Test; Calibrating The Oil Scales - Dometic GROUP WAECO AirConServiceCenter ASC5000 Instrucciones De Uso

Estación de mantenimiento de aire acondicionado
Ocultar thumbs Ver también para WAECO AirConServiceCenter ASC5000:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Service tasks

32. Disconnect the service hoses (12) and (13) and press ENTER to con-
firm.
The service hoses will now be drained. The unit is then ready for fur-
ther use.
33. Put the valve caps of the vehicle air conditioning system back on the
connections.
9
Service tasks
9.1

Leak test

In addition to the internal leak test, perform a leak test in the AirCon
Service Center every six months with an electric leak detector.
9.2

Calibrating the oil scales

NOTE
I
In order for the oil quantities and the UV additive to be measured correctly,
the zero point of the scales must be checked regularly and reset if neces-
sary.
Resetting is necessary:
 If the quantity in a container deviates by more than 10ml from the target
value
 If the AirCon Service Center has been shaken, for example during trans-
port on bumpy roads
 Every four to six weeks
1. In the basic menu, use the cursor keys
"Other selections":
2. Press ENTER to confirm.
3. Use the cursor keys
4. You are then prompted to remove the containers from the scale:
106
Short selection
Free selection
Other selections
ENTER-OK
or
to select "Reset scales":
Int. vessel filling
Flushing
Reset scales.
Service.
Remove all 3 containers
from the scales!
ENTER-OK STOP-EXIT
AirConServiceCenter
or
to select
EN