Dometic GROUP WAECO AirConServiceCenter ASC5000 Instrucciones De Uso página 122

Estación de mantenimiento de aire acondicionado
Ocultar thumbs Ver también para WAECO AirConServiceCenter ASC5000:
Idiomas disponibles
  • ES

Idiomas disponibles

Troubleshooting
Problem
The display shows
"Not enough UV. Add!"
The display shows
"Not enough oil. Add!"
The display shows
"Max. filling time
exceeded! Carry on?
The display shows
"External vessel empty or
closed valve. Check!
The display shows
"Change the equipment
drier filter! Carry on?
The display shows
"Change the vacuum pump
"
oil! Carry on?
The display shows
"Printer not in line!
"
Carry on?
The display shows
"
Error 01"
The display shows
"
Error 02"
The display shows
"Error 09"
122
Cause
This message appears dur-
ing the filling process if there
is not enough UV additive in
the container to finish the
process.
Message that appears during
the filling process if there is
not enough fresh oil in the
container to finish the pro-
cess.
Message that appears during
the filling process if the set
"
amount of refrigerant cannot
be filled.
Message that appears at the
start or during the filling of
"
the internal refrigerant con-
tainer if the set refrigerant
quantity cannot be attained.
This message appears when
you switch on the AirCon
"
Service Center.
This message appears when
you switch on the AirCon
Service Center.
Message indicates a printer
fault.
Refrigerant was added
before draining was com-
pleted.
The air conditioning system
is leaking. There is still refrig-
erant in the air conditioning
system.
Low pressure connector not
connected to the flush con-
tainer during flushing.
AirConServiceCenter
Remedy
Fill the UV additive container.
Top up the fresh oil con-
tainer with a suitable oil type.
Check that AirCon Service
Center connections are not
blocked.
Check if the external refriger-
ant container still contains
enough refrigerant or if the
valves of the external refrig-
erant container are open.
Change the internal filter as
soon as possible (see
page 108). To skip this, press
ENTER for 3 seconds.
Change the vacuum pump oil
as soon as possible (see
page 112). To skip this, press
ENTER for 3 seconds.
Check if there is paper in the
printer.
Check if the printer is
switched on (yellow LED
must light up constantly).
Check that the cover is
closed properly.
Repeat the draining proce-
dure; do not interrupt it this
time.
Fix the leak.
Connect low pressure hose
to the flush box and open
valve.