AirConServiceCenter
The following steps may only be performed by qualified personnel.
Wear protective gloves and goggles.
12. Unscrew the screw (D) from the holder, and pull the dryer filter straight
out.
13. Replace the O-rings (E). Moisten new O-rings with refrigerant oil be-
fore installing.
14. Insert the new dryer and tighten the screw to max. 15 Nm.
15. Reconnect the power plug.
16. Switch on the unit.
✓ The inverter performs a self-test.
17. Fasten the cover again.
EN
D
E
Service tasks
D
E
109