It is a requirement for the United Kingdom that the cartridges must be UKCA-compliant and must bear
the UKCA mark of compliance.
It is a requirement for the USA that the cartridges must be compliant with the stipulations set out in
ANSI A10.3-2020.
It is a requirement for the non-European member states of the C.I.P. that the cartridges must have C.I.P.
approval for the DX fastening tool used.
It is a requirement for the remaining countries that the cartridges must have passed the firing-residues
test in accordance with EN 16264 and must have a manufacturer's declaration to this effect.
Cartridges
Ordering designation
DX 6 cartridge
DX 6 cartridge
3.8
Minimum distances and edge distances
You must always observe certain minimum distances and spacing when driving fasteners. They can differ,
depending on the product.
Comply with the instructions for use in the operating instructions of the fastener used, in the Hilti
Direct Fastening Technology Manual or the corresponding local Hilti 'Technical Guide to Fastening
Technology'.
Fastening to steel
Always observe the following minimum distances and spacing when fastening to steel:
The minimum distance from the edge of the base material to the fastener must be at least 15 mm.
The minimum center-to-center distance between two fasteners is 20 mm.
The base material must have a thickness of at least 6 mm.
3.9
Information about the field of applications
See the Hilti product page for more information about the areas of application.
4
Technical data
Weight
Length (fastening tool)
Recommended maximum fastening
rate
Required contact pressure
Compression stroke
Ambient temperature (storage and
use)
4.1
Bluetooth
Frequency
Maximum emitted transmission power
4.2
Noise and vibration information
The noise values listed were determined under the following conditions:
Noise information conditions
Cartridge
Energy setting
Application
*2253453*
DX 6-GR
3.42 kg
491 mm
700 fastener driving operations/h
174 N ... 200 N
19 mm
−15 ℃ ... 50 ℃
6.8/11 caliber, black
6
Fastening 24 mm wood to concrete (C40) with X-P47 P8
2253453
Color
Power level
titanium-gray
strong
black
extra-strong
2,400 MHz ... 2,483.5 MHz
−27.2 dBm
English
23