PROGRAMMING PROCEDURE (Setting the programmer and the work times)
Attention! Before starting the gate/gate must be moved to the completely closed position. Press the "SEL" button to move the gate to this position.
• Make sure that display "D1" is off and the LEDs "L4", "L5","L6", "L7" and "L8" are all lit .
• Open the "Standard wiring diagram" which is folded inside the last page of this manual and carry out the programming procedure.
D1
PRESS THE PROG BUTTON FOR MORE
THAN 4 SECONDS: THE PARAMETER
DEFINITION LETTER "d" WILL APPEAR
ON THE DISPLAY (STAGE "A")
AFTER 1 SECOND THE DIGIT "1" WILL APPEAR
(FIRST PROGRAMMING STEP). THIS NUMBER CAN BE
EITHER FLASHING OR FIXED
ACTIVE
FUNCTION
PRESS
Dynamic button
PROG
open-close
Note 1
PRESS SEL
Automatic
PRESS
reclosing
PROG
enabled
PRESS SEL
Preflashing
PRESS
PROG
enabled
PRESS SEL
Travel limits
PRESS
enabled
PROG
PRESS SEL
Warning light
output
PRESS
PROG
fixed
PRESS SEL
Deceleration
PRESS
anabled
PROG
PRESS SEL
PRESS
SEL
WAIT FOR ABOUT 20 SECONDS WITHOUT PRESSING
ANY BUTTONS: THE PROGRAMMER WILL SAVE THE
PARAMETERS SET UP TO NOW AND WILL QUIT
PROGRAMMING.
1...4... sec.
Importing notes regarding the programmer settings
Note 1 Travel direction inversion only during the closing stage.
Note 2 The travel limits must always be enabled (number
Note 3 Deceleration must be excluded for fold up doors
Note 4 The
1... sec.
ACTIVE
FUNCTION
Dynamic button
open-block
close-block
Automatic
reclosing
excluded
Preflashing
excluded
Travel limits
excluded
Note 2
Warning light
output
intermittent
Deceleration
excluded
Note 3
PRESS
PROG
1...20... sec.
14
,
,
selection must be carried out even if deceleration is
excluded: It must be decided whether the electrical sensor works as
a travel limit in the last 1,2 or 4 seconds of movement in the closing
direction. You are advised to set a 2 second minimum
eration has been excluded you may also select
structure of the garage door could reduce the closing time after wear
and tear through time).
PRESSING THE "PROG" BUTTON WILL MOVE YOU TO
STAGE "B" . PROGRAMMING THE DECELERATION TIME.
THE VALUES CAN BE CHOSEN FROM 1 TO 4 SECONDS.
ALTERNATING
ALTERNATING
PRESS
SEL
ALTERNATING
ALTERNATING
PRESS
SEL
ALTERNATING
ALTERNATING
PRESS
SEL
PRESS
PROG
WAIT FOR ABOUT 20 SECONDS WITHOUT PRESSING
ANY BUTTONS: THE PROGRAMMER WILL SAVE THE
PARAMETERS SET UP TO NOW AND WILL QUIT
PROGRAMMING.
fixed)
; if decel-
(especially if the
Note 4
FIXED
VALUE
SELECTION
PRESS
1 SECOND
PROG
FIXED
VALUE
SELECTION
PRESS
2 SECONDS
PROG
FIXED
VALUE
SELECTION
PRESS
4 SECONDS
PROG
PRESS
SEL
1...20... sec.
CONTINUE ON PAGE 15