MAINTENANCE
11 ALARMS - ANOMALIES - USEFUL TIPS
Alarm signals, causes and possible remedies
Alarm
ALL 01
BLACK OUT
ALL 02
SMOKE TEMP.
ALL 03
REG.ENCODER
ALL 04
NO ENCODER
ALL 05
FAILED IGNITION
ALL 06
CHECK PELLETS
ALL 07
THERMAL SAFETY
ALL 08
NO DEPRESSURE
ALL 10
LOAD ALARM
CS.SB80.IST_EN_Rev. 2.0_09-23
Cause
Blackout alarm. This occurs when the electricity
is interrupted. Consult the
"Appliance's conditions
after a
blackout" table.
Faulty or disconnected flue gas temperature
sensor.
This occurs when the speed of the fume extractor
does not correspond to the set speed.
Flue gas extractor or flue gas extractor encoder
faulty. This occurs when the (tachometer) encoder
in the extractor detects an extractor speed equal
to 0.
This occurs when the minimum temperature in the
combustion chamber (Pr13) is not reached within
the maximum ignition cycle time (Pr01).
Sudden shutdown during the work phase. This
occurs when the temperature in the combustion
chamber drops below the minimum threshold
(Pr13) during the work phase.
This occurs when the door is open of has not been
closed properly during normal operation.
Occurs when the safety thermostat intervenes in
the event of pellet tank overheating (>85°C).
Occurs when the fume pressure switch intervenes
due to poor draught caused by a dirty, obstructed
or incorrectly built flue.
Occurs when the cover of the pellet tank is open or
was not properly closed.
This occurs when there is continuous loading of
pellets (the auger gearmotor does not stop for
at least 0.2 seconds during the maximum work
interval of 8.0 seconds). Before the alarm is
activated a safety relay cuts in and forcibly cuts off
the power supply to the gear motor.
Possible solution
If a power blackout occurs for a shorter time
than Pr48 (30 sec), when power is restored, the
appliance will immediately re-start in the working
mode (resuming the set working power).
If the outage lasts longer than Pr48 (30 sec), when
power is restored the appliance will enter the
"CLEANER STAND-BY" mode and run the entire
switch-off and cleaning cycle until the appliance
cools. When this phase is over, the appliance can
be restarted resuming work at the set power.
Contact the authorised KLOVER Technical
Assistance Centre.
Contact the authorised KLOVER Technical
Assistance Centre.
Contact the authorised KLOVER Technical
Assistance Centre.
Cancel the alarm and reset the appliance to
standard condition by pressing the
few seconds.
If the ignition fails, take the pellets out of the
brazier; only once all the unburned pellets have
been removed can a new ignition phase be
attempted.
Check whether there are any pellets in the tank.
Contact the authorised KLOVER Technical
Assistance Centre.
Check that the fire door is properly closed.
Manually reset the safety thermostat (see
components").
To reset the device, simply unscrew the black cap
and press the underlying button. If it "clicks", it
means that the thermostat has intervened.
Check and, if necessary, clean the fume exhaust
pipes.
Close the cover of the pellet tank if it is open.
Contact the authorised KLOVER Technical
Assistance Centre.
EN
button for a
O
"Main
37