Hilti DEG-125-P Manual De Instrucciones página 28

Ocultar thumbs Ver también para DEG-125-P:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 56
Item
Equipment
L
Clamping flange
M
Kwick-Lock (optional
for K)
4 Technical data
Right of technical changes reserved.
Tool
Rated current / power input
Rated frequency
Rated speed
Max. washer diameter
Dimensions (L x H x W) without
hood
Weight in accordance with EPTA
procedure 01/2003
Information about the power tool and applications
Drive spindle thread (arbor size)
Spindle length
Protection class
NOTE
The vibration emission level given in this information sheet has been measured in accordance with a standardised test
given in EN 60745 and may be used to compare one tool with another. It may be used for a preliminary assessment
of exposure. The declared vibration emission level represents the main applications of the tool. However if the tool is
used for different applications, with different accessories or poorly maintained, the vibration emission may differ. This
may significantly increase the exposure level over the total working period. An estimation of the level of exposure to
vibration should also take into account the times when the tool is switched off or when it is running but not actually
doing the job. This may significantly reduce the exposure level over the total working period. Identify additional safety
measures to protect the operator from the effects of vibration such as: maintain the tool and the accessories, keep
the hands warm, organisation of work patterns.
Noise information (as perEN 60745‑1):
Typical A-weighted noise power level
Typical A-weighted emission sound pressure level
Uncertainty for the given sound level
Vibration information in accordance with EN 60745
Triaxial vibration value (vibration vector sum), DEG 125-
D/-P
Surface grinding with the standard side handle, a
Surface grinding with the vibration absorbing side
handle, a
h,AG
Surface grinding with the hoop handle, a
Uncertainty (K)
All manuals and user guides at all-guides.com
AC‑D
AG-D
X
X
X
X
DEG 125-D/-P
Rated voltage
220 /230 V: 6.7 A / 1,400 W
Rated voltage 110 V: 12.2 A /
1,200 W
50 / 60 Hz
11,000/min
Diameter 125 mm
360 mm x 103 mm x 80 mm
2.3 kg
M 14
22 mm
Protection class II (double insulated)
100 dB (A)
89 dB (A)
3 dB (A)
Measured in accordance with EN 60745‑2‑3
11.3 m/s²
h,AG
7.0 m/s²
9.9 m/s²
h,AG
1.5 m/s²
AF-D
AN-D
DG‑CW
X
X
X
-
X
X
DEG 150-D/-P
Rated voltage
220 /230 V: 6.7 A / 1,400 W
Rated voltage 110 V: 12.2 A /
1,200 W
50 / 60 Hz
9,300/min
Diameter 150 mm
360 mm x 103 mm x 80 mm
2.4 kg
DC‑D
X
X
en
23
loading

Este manual también es adecuado para:

Deg-125-dDeg-150-dDeg-150-p